Here you will find information relevant to the Smart Batteries used in the Sky Scout series.

When to Return Batteries and/or Battery Chargers:

  • Red or Yellow Light on Charger: If the light is red or yellow, please return both the battery pair and the charger.

  • Note for New Customers: This issue will not affect new customers.

Battery Disconnect Failsafe at Takeoff:

  • Failsafe Functionality: If experiencing a Battery Disconnect failsafe at takeoff, the failsafe is functioning as intended. This failsafe triggers, when only one battery is discharging during takeoff, deeming an improper disconnection. Customers should unplug batteries on-at-a-time and reseat, which will clear the failsafe 99% of the time.

  • Battery Tray Update:

    • The battery tray has been updated to move the battery closer to the connector. This updated tray is now installed in all drones coming in for service or repair, as well as production drones as of 3/25/25.

    • Original Battery Tray: Failsafes with the original-style battery tray may still arise.

      • If failsafes are rare, the battery tray is within tolerance but can be replaced with the updated tray upon request.

      • If failsafes are frequent, the battery tray is out of tolerance and should be replaced under warranty.

    • It is not necessary to return the drone with its batteries, as the batteries are in working order.

Charging

Can I connect my smart battery charger to an extension cord?

How to Plug in Batteries

LED Indicator Lights on Smart Batteries

The battery will automatically begin self-discharging after five days, indicated by a blue light.

If any of these indicator light happen, and do not turn green, please follow the instructions below.

Steps to contact WISPR Support if LED lights are not green.

Contact Support for Assistance

How to Perform a Hotswap

Long Term and Short Term Storage

Pre-Arms and Failsafes

Pre-Arms:

WISPR Implores you to only override a battery failsafe in emergency situations. The battery failsafes, especially for remaining percent, are calculated to give the user the most use time that can be done safely. If you see a failsafe trigger it is in your best interest to allow it to return.

Smart Battery Data Sheet