Never go above 70/70 overlap when you plan a mission with this payload.
Zio and Vio
General Information:
Normally when connecting with a Vio, you will see an initial parameter bar load, disappear for a few seconds, and then return, but in a state where it appears to be almost done while not moving. When you see this, the Vio is downloading its parameter list.
You can verify that this is occurring by tapping the megaphone icon and looking for “Info: Mount: GREMSY VIO fw:7.7.5.0”.
On some Rangers it has been observed that the Vio can take more time to being booting and then pulling its parameter list than typically seen. This may appear as the camera remaining limp and the initial parameter bar appearing to fully finish, but not return. Allow a few minutes to pass and the camera should begin the booting process, with the parameter bar appearing in WisprGroundControl.
I only have partial control with the Zio or Vio. Zoom does not work, nor does stream swap between normal and thermal vision for the Vio.
This can be fixed by:
Completely uninstalling WISPRGroundControl then reinstalling
Booting the drone, connecting to WISPRGroundControl , and setting the payload to Vio
Reboot both the drone and WISPRGroundControl, allow the param bar to fully load the Vio firmware.
Reboot both again, and after the parameters are finished loading you should have full control.
...